NL2ZTM > BPQ32 18.10.15 00:16l 146 Lines 5292 Bytes #999 (0) @ WW
BID : 937_NL3ZTM
Read: GAST
Subj: Fwd: [BPQ32] BPQ32 scanner and debug issues
Path: DBO595<BX0RBL<CB0ESN<FRB001<NL3WAM<NL3ZZE<NL3ZTM
Sent: 151009/1936Z 937@NL3ZTM.NL3ZTM.ZH.NLD.EU BPQ1.4.64
-------- Doorgestuurd bericht --------
Onderwerp: [BPQ32] BPQ32 scanner and debug issues
Datum: 09 Oct 2015 08:58:52 -0700
Van: hans.dl5di@gmail.com [BPQ32] <BPQ32@yahoogroups.com>
Antwoord-naar: BPQ32@yahoogroups.com
Aan: BPQ32@yahoogroups.com
Hi all!
I am new to the group and hope to find sme help with a new setup.
After many years of running the pactor gateway DA5UDI with different
other software I decided to change to BPQ32.
Now I have a few issues where I could not find any helpful information
in the various documents and here in the group.
I am running version BPQ32 6.0.11.1 on Windows10 Pro 64bit.
Transceiver is an Icom IC7200 with integrated soundmodem.
I am using 2 modems to support different applications
- Modem 1 is P4Dragon for WL2K (DA5UDI)
- Modem 2 a PTC2USB for node and bbs (DA5UDI-1)
Both are connected with the new "AUD COPY" feature of the Dragon
firmware 2.10.
This part works fine.
I also use a Winmor-TNC from my former Trimode installation.
Nearly everything works fine, AXIP connects in and out, Pactor in and
out, CMR connects, applications like DX-cluster, BBS etc.
But there are a few open issues:
Issue 1:
During my step by step configuration the RIGCONTROL stopped scanning.
I am not sure why, when and do not find the reason.
It worked before and I don't get it to work again.
Connectivity is OK, I can control the trcv from the terminal, can change
QRG, filters, start outgoing calls on both modems and Winmor.
I switched off everything several times, PC, IC7200, modems, deactivated
port by port, but without any success.
The RIGCONTROL setup is in the modem configuration for the P4Dragon.
The 2 SCS modems and the Winmor TNC all use INTERLOCK=1.
It was all tested and it still works fine, but not the scanning feature.
The configuration part looks like this:
RIGCONTROL
COM3 9600 ICOM IC7200 76 PTT_SETS_INPUT
6,7.0499,USB,F2,D,P1234,W2
6,14.0934,USB,F3,D,P12,W1
6,14.1009,USB,F2,D,P1234,W2
6,14.1074,USB,F2,D,P1234,W2
6,14.1089,USB,F2,D,P1234,W2
****
I tried startscan/stopscan etc.
The SCS Pactor status windows both show "Mode: STANDBY, TX/RX State:
Receiver",
the Winmor status is "Channel State: Clear, Proto State: DISCONNECTED".
When I start the software the transceiver is switched to "14.0934 USB D"
with the correct filter, whatever it showed before.
This is the 2nd entry in my list above.
Issue 2:
I found the "DEBUG" feature for RIGCONTROL, but it obviously does not
work here.
This is the way that I added it to the setup above:
RIGCONTROL
DEBUG COM3 9600 ICOM IC7200 76 PTT_SETS_INPUT
....
It does not show anything, no output to the screen, no logfile.
However, my logfile directory is completely empty, there is no log at all,
even though that I have LOGGING=1 in the telnet server setup.
Do I need to activate something to get logfiles?
Issue3:
less important... is there a way to get a node prompt?
Something like
DL5DI de DA5UDI>
after execution of a command?
Another Question:
Can I start applications at a connect of an incoming station based on
the source callsign?
Example: one BBS always connects in for store&forward,
can I start the BBS connection automatically for that callsign, but not
for others?
Thank you for support.
Vy 73
Hans DL5DI nr Koblenz
__._,_.___
------------------------------------------------------------------------
Posted by: hans.dl5di@gmail.com
------------------------------------------------------------------------
Reply via web post
<https://groups.yahoo.com/neo/groups/BPQ32/conversations/messages/17877;_ylc=X3oDMTJydTd0bmh1BF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARtc2dJZAMxNzg3NwRzZWMDZnRyBHNsawNycGx5BHN0aW1lAzE0NDQ0MDYzMzM-?act=reply&messageNum=17877>
• Reply to sender
<mailto:hans.dl5di@gmail.com?subject=Re%3A%20BPQ32%20scanner%20and%20debug%20issues>
• Reply to group
<mailto:BPQ32@yahoogroups.com?subject=Re%3A%20BPQ32%20scanner%20and%20debug%20issues>
• Start a New Topic
<https://groups.yahoo.com/neo/groups/BPQ32/conversations/newtopic;_ylc=X3oDMTJmOTQ1YjFwBF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDZnRyBHNsawNudHBjBHN0aW1lAzE0NDQ0MDYzMzM->
• Messages in this topic
<https://groups.yahoo.com/neo/groups/BPQ32/conversations/topics/17877;_ylc=X3oDMTM3YWY4ZTduBF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARtc2dJZAMxNzg3NwRzZWMDZnRyBHNsawN2dHBjBHN0aW1lAzE0NDQ0MDYzMzMEdHBjSWQDMTc4Nzc->
(1)
Visit Your Group
<https://groups.yahoo.com/neo/groups/BPQ32/info;_ylc=X3oDMTJmcWZidXUyBF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDdnRsBHNsawN2Z2hwBHN0aW1lAzE0NDQ0MDYzMzM->
* New Members
<https://groups.yahoo.com/neo/groups/BPQ32/members/all;_ylc=X3oDMTJnOHNnYmo5BF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDdnRsBHNsawN2bWJycwRzdGltZQMxNDQ0NDA2MzMz>
3
Yahoo! Groups
<https://groups.yahoo.com/neo;_ylc=X3oDMTJlc2kxMGdxBF9TAzk3NDc2NTkwBGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDZnRyBHNsawNnZnAEc3RpbWUDMTQ0NDQwNjMzMw-->
• Privacy <https://info.yahoo.com/privacy/us/yahoo/groups/details.html>
• Unsubscribe
<mailto:BPQ32-unsubscribe@yahoogroups.com?subject=Unsubscribe> • Terms
of Use <https://info.yahoo.com/legal/us/yahoo/utos/terms/>
..
__,_._,___
Lese vorherige Mail | Lese naechste Mail
| |