OpenBCM V1.07b11 (WIN32)

Packet Radio Mailbox

DBO595

[LAU JN59RM]

 Login: GAST





  

NL2ZTM > BPQ32    18.10.15 00:16l 146 Lines 5292 Bytes #999 (0) @ WW
BID : 937_NL3ZTM
Read: GAST
Subj: Fwd: [BPQ32] BPQ32 scanner and debug issues
Path: DBO595<BX0RBL<CB0ESN<FRB001<NL3WAM<NL3ZZE<NL3ZTM
Sent: 151009/1936Z 937@NL3ZTM.NL3ZTM.ZH.NLD.EU BPQ1.4.64




-------- Doorgestuurd bericht --------
Onderwerp: 	[BPQ32] BPQ32 scanner and debug issues
Datum: 	09 Oct 2015 08:58:52 -0700
Van: 	hans.dl5di@gmail.com [BPQ32] <BPQ32@yahoogroups.com>
Antwoord-naar: 	BPQ32@yahoogroups.com
Aan: 	BPQ32@yahoogroups.com



Hi all!
I am new to the group and hope to find sme help with a new setup.
After many years of running the pactor gateway DA5UDI with different 
other software I decided to change to BPQ32.

Now I have a few issues where I could not find any helpful information 
in the various documents and here in the group.

I am running version BPQ32 6.0.11.1 on Windows10 Pro 64bit.
Transceiver is an Icom IC7200 with integrated soundmodem.
I am using 2 modems to support different applications
- Modem 1 is P4Dragon for WL2K (DA5UDI)
- Modem 2 a PTC2USB for node and bbs (DA5UDI-1)
Both are connected with the new "AUD COPY" feature of the Dragon 
firmware 2.10.
This part works fine.
I also use a Winmor-TNC from my former Trimode installation.

Nearly everything works fine, AXIP connects in and out, Pactor in and 
out, CMR connects, applications like DX-cluster, BBS etc.
But there are a few open issues:

Issue 1:
During my step by step configuration the RIGCONTROL stopped scanning.
I am not sure why, when and do not find the reason.
It worked before and I don't get it to work again.

Connectivity is OK, I can control the trcv from the terminal, can change 
QRG, filters, start outgoing calls on both modems and Winmor.
I switched off everything several times, PC, IC7200, modems, deactivated 
port by port, but without any success.

The RIGCONTROL setup is in the modem configuration for the P4Dragon.
The 2 SCS modems and the Winmor TNC all use INTERLOCK=1.
It was all tested and it still works fine, but not the scanning feature.

The configuration part looks like this:

  RIGCONTROL
  COM3 9600 ICOM IC7200 76 PTT_SETS_INPUT
  6,7.0499,USB,F2,D,P1234,W2
  6,14.0934,USB,F3,D,P12,W1
  6,14.1009,USB,F2,D,P1234,W2
  6,14.1074,USB,F2,D,P1234,W2
  6,14.1089,USB,F2,D,P1234,W2
****

I tried startscan/stopscan etc.
The SCS Pactor status windows both show "Mode: STANDBY, TX/RX State: 
Receiver",
the Winmor status is "Channel State: Clear, Proto State: DISCONNECTED".
When I start the software the transceiver is switched to "14.0934 USB D" 
with the correct filter, whatever it showed before.
This is the 2nd entry in my list above.


Issue 2:
I found the "DEBUG" feature for RIGCONTROL, but it obviously does not 
work here.
This is the way that I added it to the setup above:

  RIGCONTROL
  DEBUG COM3 9600 ICOM IC7200 76 PTT_SETS_INPUT
....

It does not show anything, no output to the screen, no logfile.

However, my logfile directory is completely empty, there is no log at all,
even though that I have LOGGING=1 in the telnet server setup.
Do I need to activate something to get logfiles?


Issue3:
less important... is there a way to get a node prompt?
Something like
DL5DI de DA5UDI>
after execution of a command?


Another Question:
Can I start applications at a connect of an incoming station based on 
the source callsign?
Example: one BBS always connects in for store&forward,
can I start the BBS connection automatically for that callsign, but not 
for others?

Thank you for support.


Vy 73


Hans DL5DI  nr Koblenz


__._,_.___
------------------------------------------------------------------------
Posted by: hans.dl5di@gmail.com
------------------------------------------------------------------------
Reply via web post 
<https://groups.yahoo.com/neo/groups/BPQ32/conversations/messages/17877;_ylc=X3oDMTJydTd0bmh1BF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARtc2dJZAMxNzg3NwRzZWMDZnRyBHNsawNycGx5BHN0aW1lAzE0NDQ0MDYzMzM-?act=reply&messageNum=17877> 
	• 	Reply to sender 
<mailto:hans.dl5di@gmail.com?subject=Re%3A%20BPQ32%20scanner%20and%20debug%20issues> 
	• 	Reply to group 
<mailto:BPQ32@yahoogroups.com?subject=Re%3A%20BPQ32%20scanner%20and%20debug%20issues> 
	• 	Start a New Topic 
<https://groups.yahoo.com/neo/groups/BPQ32/conversations/newtopic;_ylc=X3oDMTJmOTQ1YjFwBF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDZnRyBHNsawNudHBjBHN0aW1lAzE0NDQ0MDYzMzM-> 
	• 	Messages in this topic 
<https://groups.yahoo.com/neo/groups/BPQ32/conversations/topics/17877;_ylc=X3oDMTM3YWY4ZTduBF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARtc2dJZAMxNzg3NwRzZWMDZnRyBHNsawN2dHBjBHN0aW1lAzE0NDQ0MDYzMzMEdHBjSWQDMTc4Nzc-> 
(1)

Visit Your Group 
<https://groups.yahoo.com/neo/groups/BPQ32/info;_ylc=X3oDMTJmcWZidXUyBF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDdnRsBHNsawN2Z2hwBHN0aW1lAzE0NDQ0MDYzMzM-> 


  * New Members
    <https://groups.yahoo.com/neo/groups/BPQ32/members/all;_ylc=X3oDMTJnOHNnYmo5BF9TAzk3MzU5NzE0BGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDdnRsBHNsawN2bWJycwRzdGltZQMxNDQ0NDA2MzMz>
    3

Yahoo! Groups 
<https://groups.yahoo.com/neo;_ylc=X3oDMTJlc2kxMGdxBF9TAzk3NDc2NTkwBGdycElkAzE1Njk5MTI3BGdycHNwSWQDMTcwNTA2MzEwOARzZWMDZnRyBHNsawNnZnAEc3RpbWUDMTQ0NDQwNjMzMw--> 

• Privacy <https://info.yahoo.com/privacy/us/yahoo/groups/details.html> 
• Unsubscribe 
<mailto:BPQ32-unsubscribe@yahoogroups.com?subject=Unsubscribe> • Terms 
of Use <https://info.yahoo.com/legal/us/yahoo/utos/terms/>

..

__,_._,___





Lese vorherige Mail | Lese naechste Mail


 19.03.2025 11:07:36lZurueck Nach oben